今日の臨床サポート 今日の臨床サポート
関連論文:
img  2:  Hepatic arterial diameter measured with US: adjunct for US diagnosis of biliary atresia.
 
著者: Woo Sun Kim, Jung-Eun Cheon, Byung Jae Youn, So-Young Yoo, Wha Young Kim, In-One Kim, Kyung Mo Yeon, Jeong Kee Seo, Kwi-Won Park
雑誌名: Radiology. 2007 Nov;245(2):549-55. doi: 10.1148/radiol.2452061093. Epub 2007 Sep 21.
Abstract/Text PURPOSE: To prospectively evaluate the accuracy of hepatic artery diameter and hepatic artery diameter-to-portal vein diameter ratio for ultrasonographic (US) diagnosis of biliary atresia, with cholangiographic or clinical information as reference standard.
MATERIALS AND METHODS: Institutional review board approval and informed consent were obtained. US was performed in 68 neonates and infants with cholestatic jaundice (mean age, 61 days; male-to-female ratio, 38:30). Biliary atresia (n = 38) was confirmed with cholangiography, and hepatitis (n = 30) was diagnosed with clinical (n = 24) or cholangiographic (n = 6) findings. Diameter of the right hepatic artery was measured with US. Right hepatic artery diameter-to-right portal vein diameter ratio was measured to determine relative enlargement of the hepatic artery. As a control group, 17 neonates and infants (mean age, 67 days; male-to-female ratio, 12:5) without jaundice underwent US of the porta hepatis. Statistical analysis was performed to compare US parameters among three groups with one-way analysis of variance. Optimal cutoff values of the hepatic artery diameter and hepatic artery diameter-to-portal vein diameter ratio for biliary atresia diagnosis were obtained with receiver operating characteristic analysis.
RESULTS: The diameter of the right hepatic artery in biliary atresia group (1.9 mm +/- 0.4 [standard deviation]) was significantly larger than that in the hepatitis (1.4 mm +/- 0.3) and control (1.2 mm +/- 0.2) groups (P < .001). Hepatic artery diameter-to-portal vein diameter ratio in the biliary atresia group (0.52 +/- 0.12) was larger than that in hepatitis (0.40 +/- 0.07) and in control (0.40 +/- 0.10) groups (P < .001). Optimum cutoff values for diagnosis of biliary atresia were 1.5 mm (sensitivity, 92%; specificity, 87%; accuracy, 89%) for hepatic artery diameter and 0.45 for hepatic artery diameter-to-portal vein diameter ratio (sensitivity, 76%; specificity, 79%; accuracy, 78%).
CONCLUSION: Measurement of hepatic artery diameter can be helpful in the US diagnosis of biliary atresia.

PMID 17890351  Radiology. 2007 Nov;245(2):549-55. doi: 10.1148/radiol.2452061093. Epub 2007 Sep 21.
戻る

さらなるご利用にはご登録が必要です。

こちらよりご契約または優待日間無料トライアルお申込みをお願いします。

(※トライアルご登録は1名様につき、一度となります)


ご契約の場合はご招待された方だけのご優待特典があります。

以下の優待コードを入力いただくと、

契約期間が通常12ヵ月のところ、14ヵ月ご利用いただけます。

優待コード: (利用期限:まで)

ご契約はこちらから