今日の臨床サポート 今日の臨床サポート
関連論文:
img  13:  Effects of short-term pressure-controlled ventilation on gas exchange, airway pressures, and gas distribution in patients with acute lung injury/ARDS: comparison with volume-controlled ventilation.
 
著者: Maura Prella, François Feihl, Guido Domenighetti
雑誌名: Chest. 2002 Oct;122(4):1382-8.
Abstract/Text STUDY OBJECTIVES: The potential clinical benefits of pressure-controlled ventilation (PCV) over volume-controlled ventilation (VCV) in patients with acute lung injury (ALI) or ARDS still remain debated. We compared PCV with VCV in patients with ALI/ARDS with respect to the following physiologic end points: (1) gas exchange and airway pressures, and (2) CT scan intrapulmonary gas distribution at end-expiration.
DESIGN: Prospective, observational study.
SETTING: A multidisciplinary ICU in a nonuniversity, acute-care hospital.
PATIENTS: Ten patients with ALI or ARDS (9 men and 1 woman; age range, 17 to 80 years).
INTERVENTIONS: Sequential ventilation in PCV and VCV with a constant inspiratory/expiratory ratio, tidal volume, respiratory rate, and total positive end-expiratory pressure; measurement of gas exchange and airway pressures; and achievement of CT sections at lung base, hilum, and apex for the quantitative analysis of lung densities and of aerated vs nonaerated zones.
RESULTS: PaO(2), PaCO(2), and PaO(2)/fraction of inspired oxygen ratio levels did not differ between PCV and VCV. Peak airway pressure (Ppeak) was significantly lower in PCV compared with VCV (26 +/- 2 cm H(2)O vs 31 +/- 2 cm H(2)O; p < 0.001; mean +/- SEM). The surface areas of the nonaerated zones as well as the total areas at each section level were unchanged in PCV compared with VCV, except at the apex level, where there was a significantly greater nonaerated area in VCV (11 +/- 2 cm(2) vs 9 +/- 2 cm(2); p < 0.05). The total mean CT number of each lung (20 lungs from 10 patients) was similar in the two modes, as were the density values at the basal and apical levels; the hilum mean CT number was - 442 +/- 28 Hounsfield units (HU) in VCV and - 430 +/- 26 HU in PCV (p < 0.005).
CONCLUSIONS: These data show that PCV allows the generation of lower Ppeaks through the precise titration of the lung distending pressure, and might be applied to avoid regional overdistension by means of a more homogeneous gas distribution.

PMID 12377869  Chest. 2002 Oct;122(4):1382-8.
戻る

さらなるご利用にはご登録が必要です。

こちらよりご契約または優待日間無料トライアルお申込みをお願いします。

(※トライアルご登録は1名様につき、一度となります)


ご契約の場合はご招待された方だけのご優待特典があります。

以下の優待コードを入力いただくと、

契約期間が通常12ヵ月のところ、14ヵ月ご利用いただけます。

優待コード: (利用期限:まで)

ご契約はこちらから