今日の臨床サポート 今日の臨床サポート
関連論文:
img  4:  Comparative accuracy of renal duplex sonographic parameters in the diagnosis of renal artery stenosis: paired and unpaired analysis.
 
著者: Gabrielle J Williams, Petra Macaskill, Siew F Chan, Thomas E Karplus, Winkle Yung, Elisabeth M Hodson, Jonathan C Craig
雑誌名: AJR Am J Roentgenol. 2007 Mar;188(3):798-811. doi: 10.2214/AJR.06.0355.
Abstract/Text OBJECTIVE: The purpose of this study was to evaluate the test performance of duplex sonographic parameters in screening for hemodynamically significant renal artery stenosis, which occurs in approximately 5% of persons with hypertension.
MATERIALS AND METHODS: A comprehensive literature search was conducted to find studies on the diagnosis of renal artery stenosis in which duplex sonography and intraarterial angiography were compared and in which sensitivity and specificity were calculated. MEDLINE (1966-2005), EMBASE (1988-2005), and reference lists were searched and the authors contacted. Data were subjected to meta-analysis according to the hierarchical summary receiver operating characteristic curve model. Heterogeneity in test performance relating to population and design features was investigated.
RESULTS: From 1,357 titles, 88 studies involving 9,974 arteries in 8,147 patients were included. The following four parameters were evaluated: peak systolic velocity (21 studies), acceleration time (13 studies), acceleration index (13 studies), and renal-aortic ratio (13 studies). The corresponding diagnostic odds ratios (ORs) were 60.9 (95% CI, 28.3-131.2), 28.9 (95% CI, 7.1-117.2), 16.0 (95% CI, 5.1-50.6), and 29.3 (95% CI, 12.7-67.7). Results based on studies in which parameters were directly compared showed that peak systolic velocity had greater accuracy than renal-aortic ratio (relative diagnostic OR, 1.8; p = 0.03; nine studies) and acceleration index (relative diagnostic OR, 5.3; p < 0.001; five studies). Acceleration time versus acceleration index showed no evidence of a difference in accuracy (relative diagnostic OR, 1.1; p = 0.65; nine studies). Analysis of peak systolic velocity used in combination with other parameters compared with peak systolic velocity alone (seven studies) showed evidence of a shift in test positivity (p < 0.001) but only weak evidence of improvement in accuracy (relative diagnostic OR, 1.6; p = 0.09).
CONCLUSION: Sonography is a moderately accurate screening test for renal artery stenosis. The single measurement, peak systolic velocity, has the highest performance characteristics, an expected sensitivity of 85% and specificity of 92%. Additional measurements do not increase accuracy.

PMID 17312071  AJR Am J Roentgenol. 2007 Mar;188(3):798-811. doi: 10.2214/AJR.06.0355.
戻る

さらなるご利用にはご登録が必要です。

こちらよりご契約または優待日間無料トライアルお申込みをお願いします。

(※トライアルご登録は1名様につき、一度となります)


ご契約の場合はご招待された方だけのご優待特典があります。

以下の優待コードを入力いただくと、

契約期間が通常12ヵ月のところ、14ヵ月ご利用いただけます。

優待コード: (利用期限:まで)

ご契約はこちらから