今日の臨床サポート 今日の臨床サポート
関連論文:
img  13:  Early diagnosis of myocardial infarction with sensitive cardiac troponin assays.
 
著者: Tobias Reichlin, Willibald Hochholzer, Stefano Bassetti, Stephan Steuer, Claudia Stelzig, Sabine Hartwiger, Stefan Biedert, Nora Schaub, Christine Buerge, Mihael Potocki, Markus Noveanu, Tobias Breidthardt, Raphael Twerenbold, Katrin Winkler, Roland Bingisser, Christian Mueller
雑誌名: N Engl J Med. 2009 Aug 27;361(9):858-67. doi: 10.1056/NEJMoa0900428.
Abstract/Text BACKGROUND: The rapid and reliable diagnosis of acute myocardial infarction is a major unmet clinical need.
METHODS: We conducted a multicenter study to examine the diagnostic accuracy of new, sensitive cardiac troponin assays performed on blood samples obtained in the emergency department from 718 consecutive patients who presented with symptoms suggestive of acute myocardial infarction. Cardiac troponin levels were determined in a blinded fashion with the use of four sensitive assays (Abbott-Architect Troponin I, Roche High-Sensitive Troponin T, Roche Troponin I, and Siemens Troponin I Ultra) and a standard assay (Roche Troponin T). The final diagnosis was adjudicated by two independent cardiologists.
RESULTS: Acute myocardial infarction was the adjudicated final diagnosis in 123 patients (17%). The diagnostic accuracy of measurements obtained at presentation, as quantified by the area under the receiver-operating-characteristic curve (AUC), was significantly higher with the four sensitive cardiac troponin assays than with the standard assay (AUC for Abbott-Architect Troponin I, 0.96; 95% confidence interval [CI], 0.94 to 0.98; for Roche High-Sensitive Troponin T, 0.96; 95% CI, 0.94 to 0.98; for Roche Troponin I, 0.95; 95% CI, 0.92 to 0.97; and for Siemens Troponin I Ultra, 0.96; 95% CI, 0.94 to 0.98; vs. AUC for the standard assay, 0.90; 95% CI, 0.86 to 0.94). Among patients who presented within 3 hours after the onset of chest pain, the AUCs were 0.93 (95% CI, 0.88 to 0.99), 0.92 (95% CI, 0.87 to 0.97), 0.92 (95% CI, 0.86 to 0.99), and 0.94 (95% CI, 0.90 to 0.98) for the sensitive assays, respectively, and 0.76 (95% CI, 0.64 to 0.88) for the standard assay. We did not assess the effect of the sensitive troponin assays on clinical management.
CONCLUSIONS: The diagnostic performance of sensitive cardiac troponin assays is excellent, and these assays can substantially improve the early diagnosis of acute myocardial infarction, particularly in patients with a recent onset of chest pain. (ClinicalTrials.gov number, NCT00470587.)

2009 Massachusetts Medical Society
PMID 19710484  N Engl J Med. 2009 Aug 27;361(9):858-67. doi: 10.1056/NEJMoa0900428.
戻る

さらなるご利用にはご登録が必要です。

こちらよりご契約または優待日間無料トライアルお申込みをお願いします。

(※トライアルご登録は1名様につき、一度となります)


ご契約の場合はご招待された方だけのご優待特典があります。

以下の優待コードを入力いただくと、

契約期間が通常12ヵ月のところ、14ヵ月ご利用いただけます。

優待コード: (利用期限:まで)

ご契約はこちらから